Plus de 7500 articles disponibles en stock
Service & assistance personnalisés
Voir plus loin
Microscopie > Microscopes > Microscopes inversés > Olympus > CKX41 > Microscope Olympus CKX41 Fluorescence, phase, trino, 40x, 100x, 200x, 400x
N° d'article : 49700

Microscope CKX41 Fluorescence, phase, trino, 40x, 100x, 200x, 400x

13.900,00 $ TVA incluse plus frais d'expédition
Trop cher ?
à long terme
Cet article n'est plus disponible + durée de transport

Description du produit

Malheureusement, la description de l'article n'a pas encore été traduite en français, c'est pourquoi vous trouverez à la place une description en anglais.

CKX41 / CKX31 - A New Advance in Routine Inspections

Incorporation of advanced UIS2 optics ensures excellent clarity for cell checking applications

CKX series microscopes make cell checking quicker and easier than ever— because they are simple to operate, require minimal optical adjustments and capture superb observation images with outstanding efficiency. Use of a tilting observation tube, which allows the user to make observations while standing, is an especially convenient feature. In addition, the compact design allows installation right beside the incubator, improving safety and saving time spent on carrying specimens elsewhere for observation. Multiple observation methods are supported, and the range of applications has been further increased. The CKX series: designed to make routine cell checking quicker, easier and more efficient.

The UIS2 optics provide high optical performance

The UIS2 optical system combines the simplicity of the light path and the imaging excellence of a relay lenses to maintain excellent image intensity and to achieve an exceptional level of optical correction. Thanks to this feature, the UIS2 infinity-corrected optical system delivers high resolution and contrast. In addition to improved image quality, the maximum field of view has been extended to FN 22. This allows the use of various observation tubes provided for upright microscopes (patented, CKX41 only)

Enhanced clarity makes it easier to observe cell activity status

Incorporation of the world-renowned Olympus UIS2 optical system in the CKX series makes a dramatic improvement in flatness for 10 to 15% and enables very clear, high contrast images to be obtained up to the edge of the field view

Adoption of a UIS2 phase plate optimized for cell culture observation provides higher image contrast

The UIS2 phase plate adjusts the contrast according to the thickness of the cell culture, producing higher contrast images than those obtainable from conventional system

PHC type objectives minimally affected by surface tension around the container edge

The PHC type objectives are minimally affected by surface tension of the culture fluid, which can compromise clarity at the image periphery. Easier multi-well observation is one of several benefits. Combined with the improved flatness resulting from the use of UIS2 optics, this feature facilitates clear observation of cells even at the edge of the container

UIS2 infinity-corrected optical system

The advanced Olympus UIS2 optical system maximized the advantages of infinity correction. Light travels through the body tube as parallel rays as it passes through the objective. These are focused by the tube lens to form a completely aberration- free intermediate image. Attachments can be added between the objective and the built-in tube lens in the observation tube without any magnification factor alterations to total magnification. Additional correction lenses are not required The UIS2 optical system delivers optimum image quality with any configuration.

Relief contrast observations

High-resolution relief contrast with NA0.5: thick specimens like egg cells can be observed in three dimensions

Olympus' relief contrast maintains the same shadow direction even if the magnification is changed. The two-stage exchange slider uses a common aperture for 20x and 40x magnifications, so exchange between 10x/20x and 10x/40x is performed quickly. The same feature enables easy optical adjustment: by simply using the lever, the contrast can be changed while centering is being performed.

Vertical installation avoids interference with manipulators

Vertical installation helps the user to avoid accidentally touching the manipulators while operating the slider or making optical adjustments

Fluorescence observations

Fluorescence observation system with tree-position allows the use of U excitation.

Adopted renowned UIS2 optics, this system provides B and G excitations and optionally U excitation as well. All three can be provided simultaneously, with quick, easy exchange among them. Many different UIS2 filters can also

be installed, according to requirements, enabling this system to meet a wide range of fluorescence observations needs. Also, thanks to newly developed fluorescent illuminator, which secured UV transmission rate, and a variety of UIS2 fluorescent objectives, clear and high contrast fluorescent images are provided

Just set the specimen on the stage and observe immediately while standing, with no optical adjustments.

Pre-centered phase contrast slider for quick, adjustment-free observation

With the pre-centered phase contrast slider, there is no need to repeat centering each time the objective magnification is changed. Likewise, ring slit exchange when swapping between objectives is also unnecessary, since the ring slit is standardized for 10x, 20x and 40x magnifications. The CKX series makes phase contrast observations quick and easy, without optical adjustments, for much more efficient performance of routine tasks. Since the phase plate transmission rates are dictated by the objective in use, the brightness remains constant even when the magnification is changed

Tilting binocular tube for observation while standing

The binocular tube has a 30–60 degree tilting mechanism to let the researcher make observations while standing. The specimen is removed from the incubator and placed straight onto the microscope stage, so that cell checking can be done immediately. "Quick observation, quick return"—that’s the new style of routine inspection made possible by Olympus.

Slim, compact design takes up minimum laboratory space

The slim, compact design minimizes the depth of the microscope, allowing easy installation right beside the incubator or clean bench. Specimens can be taken and immediately set on the microscope stage for quick, efficient inspection.

Easy observation at the clean bench

The tilting binocular tube combination makes it unnecessary for researchers to adopt uncomfortable postures like lowering their face to the inside of the clean bench. Simply observe down the tube while working, and raise the tube afterwards: this method is much more convenient, since the clean bench can be opened/closed without moving the microscope.

CKX41 Fluorescence, phase, bino, ergo 40x, 100x, 200x, 400x

Inverses microscope stage for UIS2 optical system with trinocular tube

  • Optical system: UIS2 (Universal Infinity-corrected) optical system
  • Eyepieces: 2xWHB10x/20
  • Coarse and fine focus: coaxial
  • Plain stage: 160x250 mm, Ø35 petri dish holder stage incorporated
  • Revolving nosepiece: quadruple
  • Condenser: Fluorescence condenser; detachable ultra-long working distance (N.A. 0.3, W.D. 72 mm)
  • Filter: Greyfilter
  • Halogen lamps : 6V30W
  • Lamp house: Lightsource: HG 50 W
  • phase contrast slider: pre-centered
  • Objectives: UPLFLN4xPHP/0.13 , CACHN10xPHP/0.25 , LCACHN20xPHP/0.4 , LCACHN40xPHP/0.55
  • Dust cover, power cord

Spécifications

Optique


Echelle de l´image
4, 10, 20, 40
Nombre de objectives
4
Éclairage
Lumière transmise
Courbure de champ
Plan
Correction pour lame couvre objet
oui
Correction des couleurs
apochromatique
Suspension
oui
Condenseur
Abbe
Type de lampe
Halogène
Objectif 1
UPLFLN4XPHP/0.13 (pré-centré)
Objectif 2
CACHN10XPHP/0.25 (pré-centré)
Objetif 3
LCACHN20XPHP/0.4 (pré-centré)
Objectif 4
LCACHN40XPHP/0.55 (pré-centré)
corrigé à l'infini
oui
Grossissement
40x, 100x, 200x, 400x

Capacité


Type de lampe
6V 30W

Système mécanique


Type de construction
Trinoculaire
Mise au point
Mouvement rapide / fin
Platine porte-objet
Platine porte-objet
Revolver
4 (160x250 mm)

Particularités


Diaphragme de champ lumineux
oui
Oculaire grand champ
oui (10x/20mm grand angle)

Données générales


Largeur (mm)
237.6
Longueur (mm)
515.5
Hauteur (mm)
473.7
Série
CKX41
Poids (g)
8800

Secteurs d'application


Biologie et médecine
oui

Domaine d´emploi


Biologie Zoologie & Botanique
oui
Pathologie & histopathologie
oui

Divers


numéro de produit du fournisseur
E07MIS0009

Sécurité des produits

Fabricant:
Personne responsable: OM Digital Solutions GmbH, Willy-Brandt-Str. 23, 20457 Hamburg, DE, [email protected]

Avis clients

Il n'y a pas encore d'avis clients sur cet article.

Formulez votre propre avis :

Vous avez des questions spécifiques concernant votre commande ou votre produit? Veuillez, SVP, prendre contact avec notre service après-vente (SAV).